The Server Technology C3B36RL-2CJE0AT4 208V Basic PDU features RamLock, a self-locking, elbow-catch mechanism to prevent accidental cord disconnects on standard network power cords along with HDOT Cx, a hybrid C13/C19 outlet that accepts either an IEC C14 or C20 plug. This PDU features 18 dedicated HDOT C13 outlets and 18 HDOT Cx outlets which can be treated as either a C13 or C19 outlet.
HDOT Cx Outlets - Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
Branch Circuit Protection - This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers.
RamLock Locking Outlets - A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
Flexible Mounting - Includes standard button mounts along with provisions for custom mounting brackets.
High Temperature Rating - This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
C3B36RL-2CJE0AT4 Basic PDU Specifications
| INPUT | |
| Input Voltage (V) | 208 |
| Frequency | 50/60 Hz |
| Input Phase | 1-Phase (L-L) |
| Input Plug | NEMA L6-30P |
| Input Current (A) | 30A |
| Input Current Rated (A) | 24A |
| Input Power Capacity (kW) | 5kW |
| OUTPUT | |
| Outlet 1 Form Factor | (18) x IEC 60320/C13 North American Rating: ≤ 12A @208V L-L (15A Peak) |
| Outlet 2 Form Factor | (18) x Cx North American Rating: ≤ 16A @208V L-L (20A Peak) |
| Total Outlets | 36 (18 x C13 + 18 x Cx) |
| Branch Circuit Protection | UL489 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: ≤ 16A, 10 kAIC (North America) / (5 kAIC ROW) Interrupt Rating |
| PHYSICAL | |
| Dimensions | 70.0in tall x 2.2in wide x 2.5in deep [1778mm x 56mm x 64mm] |
| ENVIRONMENTAL | |
| Operating Environment | 32°F to 140°F / 0°C to 60°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation |
| Storage Environment | -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation |
| Quiescent / Unloaded Power Draw | < 10W for all configurations |
| COMMUNICATIONS & SECURITY | N/A |
| MEASUREMENT ACCURACY | N/A |
| CERTIFICATIONS | |
| North American | Safety (Listed & Certified, cTUVus mark) UL 62368-1 CSA C22.2 No. 62368-1 |
No resources are available for this product at this time.
Request a document below.*
For information regarding orders or shipping, please visit the Ordering Information page.
*Subject to availability