Skip to main content

Explore products on our other websites for all of your datacenter needs

Zoom the image with the mouse

C3B36RL-22kW

PRO3X Basic PDU 3-Phase 415V, 20-30A

No reviews yet
Product Code: C3B36RL-22kW
Typically in stock - usually ships 7-10 business days from receipt of order.
$1,150.00
Choose Options:

This all new Server Technology 415V 3-phase Basic PDU features RamLock, a self-locking, elbow-catch mechanism to prevent accidental cord disconnects on standard network power cords along with HDOT Cx, a hybrid C13/C19 outlet that accepts either an IEC C14 or C20 plug. The PDU features 18 dedicated HDOT C13 outlets and 18 HDOT Cx which can be treated as either a C13 or C19 outlet. Select either 20A or 30A input current and 415V 3-phase Delta or 3-phase Wye input phase for a power capacity of 11kW – 22kW for all your high power server rack needs.

Key Features of the ServerTech PRO3X Basic C3B36RL 11kW – 22kW PDU

  • HDOT Cx Outlets - Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • RamLock Locking Outlets - A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Branch Circuit Protection - This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • High Temperature Rating - This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible Mounting - Includes standard button mounts along with provisions for custom mounting brackets.
  • Color-Coded Options - Select from six colors to designate PDU circuits in the data center — black, white, red, green, blue, and yellow.  Please contact your Server Racks Online sales representative for colors other than black.

ServerTech PRO3X Basic C3B36RL 11kW – 22kW PDU Specifications:

ELECTRICAL  
Voltage 415V 3-Phase Wye 
Input Current (A) 20 or 30 amp
Outlets 18 x RamLock C13 +
18 x RamLock Combo C13/C19 (cX)
Circuit Protection 2-pole, 20A trip circuit breakers, six (6) branch, rating: ≤ 16A, 10 kAIC Interrupt Rating
Inlet NEMA L21-30P, or 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr, or 
NEMA L22-30P, or 
230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr
   
PHYSICAL  
Product 2.2W x 2.5D x 70 H (inch)
Net Weight 30 (lbs)
   
ENVIRONMENTAL  
Operating Temperature 0 to 60° (32 to 140°)
Storage Temperature -30 to 80° (-22 to 176°)
Operating Humidity 8 to 90%, non-condensing
   
COMPLIANCE  
Safety Certificates Safety (Listed & Certified, cTUVus mark)
UL 62368-1
CSA C22.2 No. 62368-1
   

 

MPN Input Current Input Current Rated (de-rated) Input Phase Input Plug Input Power Capacity
C3B36RL-GPJE0AT2 30A 24A 3-Phase Wye (L-L) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6H 17.3 kW
C3B36RL-5CJE0AT2 30A 24A 3-Phase Wye (L-L) NEMA L22-30P 17.3 kW
C3B36RL-GNJE0AT2 20A 16A 3-Phase Wye (L-L) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr 11.5 kW
  • Norton Secured
  • TRUSTe Verified
  • Accredited Business
 

This all new Server Technology 415V 3-phase Basic PDU features RamLock, a self-locking, elbow-catch mechanism to prevent accidental cord disconnects on standard network power cords along with HDOT Cx, a hybrid C13/C19 outlet that accepts either an IEC C14 or C20 plug. The PDU features 18 dedicated HDOT C13 outlets and 18 HDOT Cx which can be treated as either a C13 or C19 outlet. Select either 20A or 30A input current and 415V 3-phase Delta or 3-phase Wye input phase for a power capacity of 11kW – 22kW for all your high power server rack needs.

Key Features of the ServerTech PRO3X Basic C3B36RL 11kW – 22kW PDU

  • HDOT Cx Outlets - Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • RamLock Locking Outlets - A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Branch Circuit Protection - This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • High Temperature Rating - This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible Mounting - Includes standard button mounts along with provisions for custom mounting brackets.
  • Color-Coded Options - Select from six colors to designate PDU circuits in the data center — black, white, red, green, blue, and yellow.  Please contact your Server Racks Online sales representative for colors other than black.

ServerTech PRO3X Basic C3B36RL 11kW – 22kW PDU Specifications:

ELECTRICAL  
Voltage 415V 3-Phase Wye 
Input Current (A) 20 or 30 amp
Outlets 18 x RamLock C13 +
18 x RamLock Combo C13/C19 (cX)
Circuit Protection 2-pole, 20A trip circuit breakers, six (6) branch, rating: ≤ 16A, 10 kAIC Interrupt Rating
Inlet NEMA L21-30P, or 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr, or 
NEMA L22-30P, or 
230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr
   
PHYSICAL  
Product 2.2W x 2.5D x 70 H (inch)
Net Weight 30 (lbs)
   
ENVIRONMENTAL  
Operating Temperature 0 to 60° (32 to 140°)
Storage Temperature -30 to 80° (-22 to 176°)
Operating Humidity 8 to 90%, non-condensing
   
COMPLIANCE  
Safety Certificates Safety (Listed & Certified, cTUVus mark)
UL 62368-1
CSA C22.2 No. 62368-1
   

 

MPN Input Current Input Current Rated (de-rated) Input Phase Input Plug Input Power Capacity
C3B36RL-GPJE0AT2 30A 24A 3-Phase Wye (L-L) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6H 17.3 kW
C3B36RL-5CJE0AT2 30A 24A 3-Phase Wye (L-L) NEMA L22-30P 17.3 kW
C3B36RL-GNJE0AT2 20A 16A 3-Phase Wye (L-L) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr 11.5 kW

 

No resources are available for this product at this time.

Request a document below.*



For information regarding orders or shipping, please visit the Ordering Information page.

*Subject to availability

Customer Reviews