Skip to main content
Zoom the image with the mouse

Austin Hughes Basic Series 208V Combo X19

208V - Combo C13/C19 (slide lock) - Basic PDU

No reviews yet
Product Code: Basic Series 208V Combo X19
MSRP: $327.00
$283.00
(You save $44.00 )
Choose Options:

InfraPower 208V - combo C13/C19 (slide lock) - Basic PDU:
Current: 20A or 30A
Voltage: 208V Single-Phase
Input Plug: L6-20P or L6-30P plug
Input Cord: 10ft UL SJT 12 AWG cordset
Outlets: C13/C19 Combo Slide-locking Outlets (X19)
Circuit Breakers: (1 or 2) 1-pole MCB
Mounting: 0U Vertical

The InfraPower Basic Series 208V Combo X19 Rack PDU is single-phase PDU designed for cost efficient, reliable power distribution for your rack. Multiple outlet configurations are available in horizontal or vertical form factors. Now with the innovative slide-locking outlets. 

Infrapower Basic 208V X19 PDU Specifications:

ELECTRICAL  
Voltage 208V Single-Phase
Rated Amperage 20 or 30 amp
Outlets Locking Combo C13/C19 (X19) 
Circuit Protection 1 or 2 Hydraulic MCBs
Single Circuit (20A): 16Amax
Circuit A & B (30A) : 12Amax
Inlet NEMA L6-20P or  L6-30P
10ft cordset3W 10AWG UL SJT
   
PHYSICAL  
Product 2.2W x 2.2D x 31.5-65.4 H (inch)
Package 4.3W x 2.2D x 43.0-80.4 H (inch)
Gross Weight 11-18 (lbs)
Net Weight 9-15 (lbs)
   
ENVIRONMENTAL  
Operating Temperature -5 to 60° (23 to 140°)
Storage Temperature -25 to 65° (-25 to 149°)
Operating Humidity 0 to 95%, non-condensing
Operational Altitude 0 to 2,000 m
Storage Altitude 0 to 15,000 m
   
COMPLIANCE  
EMC Certificates FCC : FCC 47 CFR Part 15 Subpart B, ICES-003 Issue 7
Safety Certificates CB : IEC 62368-1:2014
UL-US : UL 62368-1, 2nd Ed.
UL-CA : CSAC22.2 No. 62368-1-14, 2nd Ed.
Environment RoHS, Reach & WEEE
   

 

MPN Amps Outlets Input Plug Circuit Protection
V8X19-20A/CR_L620/3B-1 20 8 x X19 L6-20P 1 x MCB 16A max
V8X19-30A/CR_L630/3B-1 30 8 x X19 L6-30P 2 x MCB 12A max per Circuit
V12X19-20A/CR_L620/3B-1 20 12 x X19 L6-20P 1 x MCB 16A max
V12X19-30A/CR_L630/3B-1 30 12 x X19 L6-30P 2 x MCB 12A max per Circuit
V16X19-20A/CR_L620/3B-1 20 16 x X19 L6-20P 1 x MCB 16A max
V16X19-30A/CR_L630/3B-1 30 16 x X19 L6-30P 2 x MCB 12A max per Circuit
V20X19-20A/CR_L620/3B-1 20 20 x X19 L6-20P 1 x MCB 16A max
V20X19-30A/CR_L630/3B-1 30 20 x X19 L6-30P 2 x MCB 12A max per Circuit
V24X19-20A/CR_L620/3B-1 20 24 x X19 L6-20P 1 x MCB 16A max
V24X19-30A/CR_L630/3B-1 30 24 x X19 L6-30P 2 x MCB 12A max per Circuit
V30X19-20A/CR_L620/3B-1 20 30 x X19 L6-20P 1 x MCB 16A max
V30X19-30A/CR_L630/3B-1 30 30 x X19 L6-30P 2 x MCB 12A max per Circuit
V36X19-20A/CR_L620/3B-1 20 36 x X19 L6-20P 1 x MCB 16A max
V36X19-30A/CR_L630/3B-1 30 36 x X19 L6-30P 2 x MCB 12A max per Circuit

 

 

InfraPower 208V - combo C13/C19 (slide lock) - Basic PDU:
Current: 20A or 30A
Voltage: 208V Single-Phase
Input Plug: L6-20P or L6-30P plug
Input Cord: 10ft UL SJT 12 AWG cordset
Outlets: C13/C19 Combo Slide-locking Outlets (X19)
Circuit Breakers: (1 or 2) 1-pole MCB
Mounting: 0U Vertical

The InfraPower Basic Series 208V Combo X19 Rack PDU is single-phase PDU designed for cost efficient, reliable power distribution for your rack. Multiple outlet configurations are available in horizontal or vertical form factors. Now with the innovative slide-locking outlets. 

Infrapower Basic 208V X19 PDU Specifications:

ELECTRICAL  
Voltage 208V Single-Phase
Rated Amperage 20 or 30 amp
Outlets Locking Combo C13/C19 (X19) 
Circuit Protection 1 or 2 Hydraulic MCBs
Single Circuit (20A): 16Amax
Circuit A & B (30A) : 12Amax
Inlet NEMA L6-20P or  L6-30P
10ft cordset3W 10AWG UL SJT
   
PHYSICAL  
Product 2.2W x 2.2D x 31.5-65.4 H (inch)
Package 4.3W x 2.2D x 43.0-80.4 H (inch)
Gross Weight 11-18 (lbs)
Net Weight 9-15 (lbs)
   
ENVIRONMENTAL  
Operating Temperature -5 to 60° (23 to 140°)
Storage Temperature -25 to 65° (-25 to 149°)
Operating Humidity 0 to 95%, non-condensing
Operational Altitude 0 to 2,000 m
Storage Altitude 0 to 15,000 m
   
COMPLIANCE  
EMC Certificates FCC : FCC 47 CFR Part 15 Subpart B, ICES-003 Issue 7
Safety Certificates CB : IEC 62368-1:2014
UL-US : UL 62368-1, 2nd Ed.
UL-CA : CSAC22.2 No. 62368-1-14, 2nd Ed.
Environment RoHS, Reach & WEEE
   

 

MPN Amps Outlets Input Plug Circuit Protection
V8X19-20A/CR_L620/3B-1 20 8 x X19 L6-20P 1 x MCB 16A max
V8X19-30A/CR_L630/3B-1 30 8 x X19 L6-30P 2 x MCB 12A max per Circuit
V12X19-20A/CR_L620/3B-1 20 12 x X19 L6-20P 1 x MCB 16A max
V12X19-30A/CR_L630/3B-1 30 12 x X19 L6-30P 2 x MCB 12A max per Circuit
V16X19-20A/CR_L620/3B-1 20 16 x X19 L6-20P 1 x MCB 16A max
V16X19-30A/CR_L630/3B-1 30 16 x X19 L6-30P 2 x MCB 12A max per Circuit
V20X19-20A/CR_L620/3B-1 20 20 x X19 L6-20P 1 x MCB 16A max
V20X19-30A/CR_L630/3B-1 30 20 x X19 L6-30P 2 x MCB 12A max per Circuit
V24X19-20A/CR_L620/3B-1 20 24 x X19 L6-20P 1 x MCB 16A max
V24X19-30A/CR_L630/3B-1 30 24 x X19 L6-30P 2 x MCB 12A max per Circuit
V30X19-20A/CR_L620/3B-1 20 30 x X19 L6-20P 1 x MCB 16A max
V30X19-30A/CR_L630/3B-1 30 30 x X19 L6-30P 2 x MCB 12A max per Circuit
V36X19-20A/CR_L620/3B-1 20 36 x X19 L6-20P 1 x MCB 16A max
V36X19-30A/CR_L630/3B-1 30 36 x X19 L6-30P 2 x MCB 12A max per Circuit

 


 

No resources are available for this product at this time.

Request a document below.*



For information regarding orders or shipping, please visit the Ordering Information page.

*Subject to availability

Customer Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Vendor Independent

Vendor Independent

Find the Best Solution for your Needs
BBB A+

BBB A+

With 25+ Years of Excellent Service
Over 5,000 products

Over 5,000 products

Find what fits your needs

Outstanding Customer Service

Real People. Ready to Help.