Server Tech Sentry Smart PDU, 0U (CS-54VDY-L2130)

Please note, the ServerTech CS-54VDY-L2130 PDU has been discontinued. For replacement options, please contact your Server Racks Online sales representative.

The Server Technology CS-54VDY-L2130 is a 0U, 54 mixed outlet, 30A, 3-Phase Wye, 208V, NEMA L21-30P, Sentry Smart Rack PDU.

The Smart Cabinet Distribution Units (CDU) provide reliable power distribution combined with local and remote power monitoring and environmental monitoring via IP. Use the network interface to view power, temperature and humidity levels via Web browser, or receive SNMP based alarms when conditions exceed defined thresholds.  The Smart CDU is also supported by our Enterprise View CDU Manager. This gives the network administrator the ability to view and access multiple Smart CDU's from multiple locations via a single Web interface.

Server Tech CS-54VDY-L2130 Features:

  • Input Current Monitor: Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display.  Remote verification via web browser or serial screen.
  • High Power Distribution: 120V 208V and three-phase power options; 20 or 30-Amp power input feed options.
  • High Density: Dual input feed; 54 outlets per enclosure.
  • IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS and RS-232 access
  • Environmental Monitoring: Each Smart CDU supports two external temperature & humidity probes and reports conditions thru the Web interface
  • Enterprise View: View and access multiple Smart CDUs from one Web interface.
  • SNMP Traps: Provide automated alerts for power and environmental conditions
Server Tech Sentry Smart PDU, 0U (CS-54VDY-L2130) - Click to enlarge

Server Technology

Price
$1,490.00
Rack UnitsZero U
Dimensions66"H x 3.5"W x 2.25"D

Mounting Bracket Options
Include Mounting Bracket KIT-MBVPT-1B (no charge)
No Mounting Bracket Needed

Server Tech CS-54VDY-L2130 Specifications:

Mechanical  
Height 66 in. (1676 mm.)
Width 3.5 in. (89 mm.)
Depth 2.25 in. (57 mm.)
Input  
Available Input Voltages 3-Phase Wye, 208V, 50/60Hz
Available Input Cord NEMA L21-30P Cord Set, 10 ft (3m)
Output  
Outlets (12) NEMA 5-20R
(42) IEC 60320/C13
Amperage 30A
Branch Circuit Protection Compliant to UL 60950-1
Communications

10/100 BaseT Ethernet
HTTP/HTTPS
SSLv3/TLSv1
SNMPv2
SSHv2
Telnet
LDAPv3/LDAPS
TACACS+
RADIUS
RS-232 (Serial)

Standards

cTUVus – UL 60950-1-2003
CAN/CSA 22.2 No. 60950-1:2003
TUVGS – EN 60950-1:2001
FCC Class A, Part 15
CE
EMC-EN 55022 Class A, EN 55024

Server Tech Smart PDU Additional Features:

  • Branch Circuit Protection- The Sentry CDU Family meets the UL 60950-1 requirement for branch circuit protection. Attention! The Sentry CDU products meet the above criteria by providing overcurrent protection with UL-listed Bussman SC fuses for each branch circuit.

  • Input Current Monitoring- The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.

  • Temperature and Humidity The Smart CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

  • Remote Power Monitoring- Monitor input power via IP or serial interface.

  • HTTP/HTTPs Web Configuration & Control- Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

  • SNMP Management & Event Notification- The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

  • Zero U Enclosure- A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

  • Secure Access - SSH or SSL Protection- Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device. Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.

  • Integrated Temp/Humidity Probe Support- Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

  • Firmware Flash Upgradeable- Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets. Click here for the latest Firmware update.

  • LDAP/LDAPS- The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
    This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.  Sentry LDAP support has been tested in the following environments:

    • Microsoft Active Directory (MSAD)
    • Novell eDirectory (eDir)
    • Open LDAP
  • RS-232 Control- Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.



Question: How do I order this item?
Answer: Thank you for inquiry. Due to the customizable nature of this smart, monitored PDU, a consultative purchase process is required. If you are interested in purchasing one of Server Technology's Smart Cabinet Distribution Units (CDU), please speak with one of our sales engineers by calling 1-866-722-5776.

Question: What is the replacement part# for CS-54VDY-L2130. We use these in some og our test stations and we are building some new stations and we need something close to this as far a configuration and mounting size
Answer: Thank you for your inquiry. We just heard back from the manufacturer and unfortunately there is no direct replacement for the CS-54VDY-L2130. One potential replacement suggested was the C2S42CE-YCMFAM00, but it looks like the dimensions are a little different. The suggested replacement is 70.0in tall x 2.2in wide x 2.5in deep. The discontinued PDU is 66in high x 3.5in wide x 2.25in deep. Additional specs on the manufacturer suggested replacement are: Smart Master PRO2 (42) C13 Alt Phase HDOT + (3) NEMA 5-20R Utility Outlets, 208V 3PH Wye 3BR 30A L21-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Base Cord Entry, Doghouse Breakers, Phase Monitoring. The data sheet can be found here: https://datasheets.servertech.com/data... If you are interested in ordering this particular model, or would like to discuss other options, please contact your Server Racks Online representative at 1-866-722-5776 or via our online chat feature.