Skip to main content
New
Zoom the image with the mouse

Vertiv CDU

Vertiv™ CoolChip CDU: Advanced Liquid Cooling for High-Density Data Centers

No reviews yet
Product Code: CDU
Choose Options:
Contact for Pricing

Contact us for current pricing, availability, and configuration options.


Next-Generation Coolant Distribution Units for AI, HPC, and High-Density Computing

As data center workloads continue to grow, traditional air cooling solutions are reaching their limits. Artificial intelligence (AI), machine learning, high-performance computing (HPC), and advanced enterprise applications are driving unprecedented rack densities that require more efficient thermal management strategies.

The Vertiv™ CoolChip CDU (Coolant Distribution Unit) provides a scalable liquid cooling solution designed to support the next generation of high-density computing environments. Engineered for direct-to-chip cooling and rear door heat exchanger (RDHx) applications, the CoolChip CDU enables data centers to efficiently manage high-power IT loads while maintaining precise temperature control, system reliability, and operational flexibility.

With flexible deployment options, advanced monitoring capabilities, and cooling capacities ranging from compact in-rack solutions to large-scale data center deployments, Vertiv CoolChip CDU systems help organizations transition to liquid cooling without unnecessary infrastructure complexity.

 

 


Why Choose the Vertiv CoolChip CDU?

Designed for High-Density AI and HPC Workloads

Modern processors, GPUs, and AI accelerators generate significantly more heat than traditional server hardware. The Vertiv CoolChip CDU helps overcome these thermal challenges by efficiently distributing coolant to high-density racks and supporting liquid-cooled IT equipment.

By enabling direct-to-chip cooling and rear door heat exchanger applications, CoolChip CDU systems allow organizations to deploy higher-performance computing infrastructure while maintaining stable operating conditions.

Ideal Applications Include:

  • Artificial intelligence (AI) infrastructure
  • Machine learning clusters
  • High-performance computing (HPC)
  • Hyperscale data centers
  • Colocation facilities
  • Enterprise data centers
  • Government computing environments
  • Healthcare and research facilities
  • Edge computing deployments

Key Benefits of Vertiv CoolChip CDU

Flexible Liquid Cooling Deployment Options

Every data center has unique infrastructure requirements. Vertiv CoolChip CDU systems are designed to support multiple architectures, including:

  • In-rack deployment
  • In-row installation
  • End-of-row placement
  • Perimeter-based configurations

The platform supports both liquid-to-liquid and liquid-to-air heat exchanger configurations, allowing organizations to select the cooling architecture that best fits their facility design.

CDU model 70 121 600 1350 2300
CDU type Liquid-to-Air Liquid-to-Liquid Liquid-to-Liquid Liquid-to-Liquid Liquid-to-Liquid
Nominal cooling
capacity*
70 kW at 11°C Approach
Temperature Difference (ATD)
121 kW at 4°C Approach
Temperature Difference (ATD)
600 kW at 4°C Approach
Temperature Difference (ATD)
1368 kW at 4°C Approach
Temperature Difference (ATD)
2300 kW at 4°C Approach
Temperature Difference (ATD)
Nominal fluid
flow rate
60 l/min
(15.8 gpm)
120 l/min
(31.7 gpm)
900 l/min
(238 gpm)
1200 l/min
(317 gpm)
3400 l/min
(898 gpm)
Maximum airflow,
(N+1 operation)
10,100 CMH
(5,945 CFM)
n/a n/a n/a n/a
Unit dimensions
(H x W x D),
in (mm)
91 x 24 x 48
(2300 x 600 x 1200)
6.89 x 17.52 x 33.46
(175 x 445 x 850)
78.7 x 23.6 x 47.2
(2000 x 600 x 1200)
81.6 x 35.4 x 48.9
(2069 x 900 x 1243)
94.5 x 48 x 48
(2400 x 1200 x 1200)
Power supply 115V, 1PH, 60Hz
230V, 1PH, 50Hz
110-120V, 1PH, 50/60Hz
208V-240V, 1PH, 50/60Hz
46V-52V VDC
400V, 3PH, 50/60Hz
480V, 3PH, 60Hz
400V, 3PH, 50/60Hz
480V, 3PH, 60Hz
400V, 3PH, 50/60Hz
480V, 3PH, 60Hz

*Please contact a sales representative for unit performance data based on site conditions.


Support for Higher Rack Densities

As rack power requirements continue increasing, liquid cooling provides a more efficient method for removing heat compared to traditional air-based cooling.

The Vertiv CoolChip CDU helps manage high-density workloads by delivering coolant directly where heat is generated, supporting advanced processors and GPU-intensive applications while helping maintain optimal operating temperatures.


Improved Efficiency and Reduced Total Cost of Ownership

Liquid cooling can improve thermal efficiency by reducing dependence on traditional cooling infrastructure. Vertiv CoolChip CDU systems are designed to provide efficient cooling performance while helping reduce long-term operational costs associated with high-density deployments.

Benefits include:

  • Improved cooling efficiency
  • Higher rack density capability
  • Reduced cooling infrastructure requirements
  • More efficient use of available data center space
  • Easier scaling for future computing demands

Enhanced Reliability and Protection

Protecting expensive IT hardware is critical in any liquid cooling deployment. The Vertiv CoolChip CDU incorporates features designed to maintain fluid quality, provide system redundancy, and support reliable operation.

Key reliability features include:

  • Redundant pump architecture
  • Built-in filtration
  • Leak detection support
  • Unit-to-unit communication capabilities
  • Wetted material compatibility designed to protect secondary liquid networks

Vertiv CoolChip CDU Features

Precision Temperature Control

Maintaining consistent coolant temperatures is essential for protecting sensitive processors and GPUs. Vertiv CoolChip CDU systems provide precise temperature management to help prevent thermal shock and maintain stable IT equipment performance.


Integrated Filtration System

A built-in 50-micron filter helps maintain coolant quality by reducing contaminants within the secondary fluid loop. This helps protect server components and supports long-term system reliability.


Intelligent Flow Monitoring and Alarm Capabilities

Advanced monitoring features help operators maintain visibility into cooling performance.

Capabilities include:

  • Coolant flow monitoring
  • System alarms
  • Performance tracking
  • Remote communication integration

These features help data center teams quickly identify potential issues before they impact critical infrastructure.


Easy Maintenance and Serviceability

Vertiv CoolChip CDU systems are designed with serviceability in mind. Accessible fill ports, drain locations, and integrated controls simplify installation, maintenance, and ongoing operation.


Durable Stainless-Steel Construction

Innovative stainless-steel construction and hygienic couplings help maintain secondary fluid network integrity while supporting dependable long-term operation.


Vertiv CoolChip CDU Cooling Capacities

The Vertiv CoolChip CDU family provides scalable cooling options for environments ranging from individual high-density racks to large enterprise and hyperscale deployments.

Available configurations include:

Model Capacity Cooling Application
70 kW Liquid-to-air cooling applications
100+ kW Compact in-rack direct-to-chip cooling
450 kW High-density liquid cooling deployments
600 kW Enterprise and data center liquid cooling
1,350 kW Large-scale high-density environments
2,300 kW Hyperscale and advanced computing facilities

 


Technical Specifications Overview

Controls & Monitoring

  • Color touchscreen display
  • Modbus RTU (RS485) communication
  • TCP/IP communication support
  • Integrated monitoring capabilities

Core Components

  • Variable-speed redundant pumps
  • Integrated filtration
  • Advanced coolant management controls
  • Leak detection support

Certifications

  • CE
  • cULus
  • RoHS

 


Future-Proof Your Data Center With Vertiv CoolChip CDU

The demand for higher computing performance is accelerating, and thermal management strategies must evolve alongside new processor technologies. Vertiv CoolChip CDU provides a scalable path toward liquid cooling adoption, helping organizations support AI, HPC, and next-generation workloads with confidence.

Whether you are upgrading an existing data center or designing a new high-density computing environment, Vertiv CoolChip CDU delivers the efficiency, reliability, and flexibility needed for modern infrastructure.

 

Next-Generation Coolant Distribution Units for AI, HPC, and High-Density Computing

As data center workloads continue to grow, traditional air cooling solutions are reaching their limits. Artificial intelligence (AI), machine learning, high-performance computing (HPC), and advanced enterprise applications are driving unprecedented rack densities that require more efficient thermal management strategies.

The Vertiv™ CoolChip CDU (Coolant Distribution Unit) provides a scalable liquid cooling solution designed to support the next generation of high-density computing environments. Engineered for direct-to-chip cooling and rear door heat exchanger (RDHx) applications, the CoolChip CDU enables data centers to efficiently manage high-power IT loads while maintaining precise temperature control, system reliability, and operational flexibility.

With flexible deployment options, advanced monitoring capabilities, and cooling capacities ranging from compact in-rack solutions to large-scale data center deployments, Vertiv CoolChip CDU systems help organizations transition to liquid cooling without unnecessary infrastructure complexity.

 

 


Why Choose the Vertiv CoolChip CDU?

Designed for High-Density AI and HPC Workloads

Modern processors, GPUs, and AI accelerators generate significantly more heat than traditional server hardware. The Vertiv CoolChip CDU helps overcome these thermal challenges by efficiently distributing coolant to high-density racks and supporting liquid-cooled IT equipment.

By enabling direct-to-chip cooling and rear door heat exchanger applications, CoolChip CDU systems allow organizations to deploy higher-performance computing infrastructure while maintaining stable operating conditions.

Ideal Applications Include:

  • Artificial intelligence (AI) infrastructure
  • Machine learning clusters
  • High-performance computing (HPC)
  • Hyperscale data centers
  • Colocation facilities
  • Enterprise data centers
  • Government computing environments
  • Healthcare and research facilities
  • Edge computing deployments

Key Benefits of Vertiv CoolChip CDU

Flexible Liquid Cooling Deployment Options

Every data center has unique infrastructure requirements. Vertiv CoolChip CDU systems are designed to support multiple architectures, including:

  • In-rack deployment
  • In-row installation
  • End-of-row placement
  • Perimeter-based configurations

The platform supports both liquid-to-liquid and liquid-to-air heat exchanger configurations, allowing organizations to select the cooling architecture that best fits their facility design.

CDU model 70 121 600 1350 2300
CDU type Liquid-to-Air Liquid-to-Liquid Liquid-to-Liquid Liquid-to-Liquid Liquid-to-Liquid
Nominal cooling
capacity*
70 kW at 11°C Approach
Temperature Difference (ATD)
121 kW at 4°C Approach
Temperature Difference (ATD)
600 kW at 4°C Approach
Temperature Difference (ATD)
1368 kW at 4°C Approach
Temperature Difference (ATD)
2300 kW at 4°C Approach
Temperature Difference (ATD)
Nominal fluid
flow rate
60 l/min
(15.8 gpm)
120 l/min
(31.7 gpm)
900 l/min
(238 gpm)
1200 l/min
(317 gpm)
3400 l/min
(898 gpm)
Maximum airflow,
(N+1 operation)
10,100 CMH
(5,945 CFM)
n/a n/a n/a n/a
Unit dimensions
(H x W x D),
in (mm)
91 x 24 x 48
(2300 x 600 x 1200)
6.89 x 17.52 x 33.46
(175 x 445 x 850)
78.7 x 23.6 x 47.2
(2000 x 600 x 1200)
81.6 x 35.4 x 48.9
(2069 x 900 x 1243)
94.5 x 48 x 48
(2400 x 1200 x 1200)
Power supply 115V, 1PH, 60Hz
230V, 1PH, 50Hz
110-120V, 1PH, 50/60Hz
208V-240V, 1PH, 50/60Hz
46V-52V VDC
400V, 3PH, 50/60Hz
480V, 3PH, 60Hz
400V, 3PH, 50/60Hz
480V, 3PH, 60Hz
400V, 3PH, 50/60Hz
480V, 3PH, 60Hz

*Please contact a sales representative for unit performance data based on site conditions.


Support for Higher Rack Densities

As rack power requirements continue increasing, liquid cooling provides a more efficient method for removing heat compared to traditional air-based cooling.

The Vertiv CoolChip CDU helps manage high-density workloads by delivering coolant directly where heat is generated, supporting advanced processors and GPU-intensive applications while helping maintain optimal operating temperatures.


Improved Efficiency and Reduced Total Cost of Ownership

Liquid cooling can improve thermal efficiency by reducing dependence on traditional cooling infrastructure. Vertiv CoolChip CDU systems are designed to provide efficient cooling performance while helping reduce long-term operational costs associated with high-density deployments.

Benefits include:

  • Improved cooling efficiency
  • Higher rack density capability
  • Reduced cooling infrastructure requirements
  • More efficient use of available data center space
  • Easier scaling for future computing demands

Enhanced Reliability and Protection

Protecting expensive IT hardware is critical in any liquid cooling deployment. The Vertiv CoolChip CDU incorporates features designed to maintain fluid quality, provide system redundancy, and support reliable operation.

Key reliability features include:

  • Redundant pump architecture
  • Built-in filtration
  • Leak detection support
  • Unit-to-unit communication capabilities
  • Wetted material compatibility designed to protect secondary liquid networks

Vertiv CoolChip CDU Features

Precision Temperature Control

Maintaining consistent coolant temperatures is essential for protecting sensitive processors and GPUs. Vertiv CoolChip CDU systems provide precise temperature management to help prevent thermal shock and maintain stable IT equipment performance.


Integrated Filtration System

A built-in 50-micron filter helps maintain coolant quality by reducing contaminants within the secondary fluid loop. This helps protect server components and supports long-term system reliability.


Intelligent Flow Monitoring and Alarm Capabilities

Advanced monitoring features help operators maintain visibility into cooling performance.

Capabilities include:

  • Coolant flow monitoring
  • System alarms
  • Performance tracking
  • Remote communication integration

These features help data center teams quickly identify potential issues before they impact critical infrastructure.


Easy Maintenance and Serviceability

Vertiv CoolChip CDU systems are designed with serviceability in mind. Accessible fill ports, drain locations, and integrated controls simplify installation, maintenance, and ongoing operation.


Durable Stainless-Steel Construction

Innovative stainless-steel construction and hygienic couplings help maintain secondary fluid network integrity while supporting dependable long-term operation.


Vertiv CoolChip CDU Cooling Capacities

The Vertiv CoolChip CDU family provides scalable cooling options for environments ranging from individual high-density racks to large enterprise and hyperscale deployments.

Available configurations include:

Model Capacity Cooling Application
70 kW Liquid-to-air cooling applications
100+ kW Compact in-rack direct-to-chip cooling
450 kW High-density liquid cooling deployments
600 kW Enterprise and data center liquid cooling
1,350 kW Large-scale high-density environments
2,300 kW Hyperscale and advanced computing facilities

 


Technical Specifications Overview

Controls & Monitoring

  • Color touchscreen display
  • Modbus RTU (RS485) communication
  • TCP/IP communication support
  • Integrated monitoring capabilities

Core Components

  • Variable-speed redundant pumps
  • Integrated filtration
  • Advanced coolant management controls
  • Leak detection support

Certifications

  • CE
  • cULus
  • RoHS

 


Future-Proof Your Data Center With Vertiv CoolChip CDU

The demand for higher computing performance is accelerating, and thermal management strategies must evolve alongside new processor technologies. Vertiv CoolChip CDU provides a scalable path toward liquid cooling adoption, helping organizations support AI, HPC, and next-generation workloads with confidence.

Whether you are upgrading an existing data center or designing a new high-density computing environment, Vertiv CoolChip CDU delivers the efficiency, reliability, and flexibility needed for modern infrastructure.


 







No resources are available for this product at this time.

Request a document below.*



For information regarding orders or shipping, please visit the Ordering Information page.

*Subject to availability

Customer Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Vendor Independent

Vendor Independent

Find the Best Solution for your Needs
BBB A+

BBB A+

With 25+ Years of Excellent Service
Over 5,000 products

Over 5,000 products

Find what fits your needs

Outstanding Customer Service

Real People. Ready to Help.