ServerTech -48VDC Switched PDU, 4x70A Inputs / 4x70A Outputs

Server Technology 48DCWB-04-4X070-DONB Switched DC PDU

  • Inputs: (4) -48VDC (-40 to -60) Input Terminal Blocks (+/- & G)
  • Rated Amperage: 70A each, 280A total
  • Typical Power: 13.4kW
  • Outputs: High Current: (4) 70A
  • Circuit Protection: TPC Fuses
  • Form Factor: 2.5U Horizontal x 16" Deep - 19" EIA Mounting

The Sentry Switched -48VDC Rack Power Distribution Unit (CDU / PDU) is an intelligent DC power solution that combines the functions of a power distribution panel and remote power management unit into a compact 19"rack-mounted enclosure. -48VDC Rack CDU eliminates the need to dispatch a field service technician for manual intervention when routers, servers and other mission critical network devices lock-up. Key features Include remote monitoring and management, Temperature & Humidity Monitoring, 'always-on' technology for the highest level of fault tolerance, and reboot commands to connected servers, switches and network equipment.

Download IconServerTech -48VDC Family Brochure (PDF)

Server Tech 48DCWB-04-4X070-DONB - Click to enlarge

Server Technology

Price
$3,774.00
Dimensions2.5U, 17"W x 4.4"H x 16"D (432 x 112 x 407mm)

TCP Fuse Option
4 x FUSE-TPC-10: 10A Fuses (+$0)
4 x FUSE-TPC-15: 15A Fuses (+$0)
4 x FUSE-TPC-20: 20A Fuses (+$0)
4 x FUSE-TPC-25: 25A Fuses (+$0)
4 x FUSE-TPC-30: 30A Fuses (+$0)
4 x FUSE-TPC-40: 40A Fuses (+$0)
4 x FUSE-TPC-50: 50A Fuses (+$0)
4 x FUSE-TPC-60: 60A Fuses (+$0)
4 x FUSE-TPC-75: 75A Fuses (+$0)

Key Features:

Fuses - Icon

Fused Power Output Protection
Each low and high current output are individually protected by their own fuse. A variety of current capacities are available. Both the low current GMT and high current TPC fuses have a visual indicator when blown.

Dual Power - Icon

Dual 100-300A DC Power Input Feeds
Distribute 100-300A of DC power through low and high current outputs. Each output circuit is designed with their own over-current protection.

Environmental Monitoring - Icon

Environmental Monitoring
External probes, with 3-meter cable, capable of measuring temperature & humidity. Receive SNMP-based or email alert notifications when conditions exceed defined thresholds.

Communications - Icon

IP Access, Security & Communications
Web interface, SSL, SSH, Telnet, SNMP & RS-232 access, 10/100 Base T-Ethernet, SSLv3/TLSv1, SNMPv2c & v3, RADIUS, TACACS+, LDAP, LDAPS, DHCP, SMTP/Email, and Syslog.

Remote Power Control
Individual or group outlet remote power control to cycle power and reboot any selected server(s) or other network device(s). Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry Cabinet PDU and rectify locked-up network devices. Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group. Reduce Mean Time to Repair (MTTR) a failing server by controlling individual power outlet receptacles to reboot any selected server or other device.

Expansion Tower PDU
Connect an Expansion Cabinet power distribution unit to the Cabinet PDU to control two power input circuits and manage outlets (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers

Agency Approvals

  • TUV-GS marked to EN 60950-1:2006 + A11
  • cTUVus marked to UL 60950-1:2007 and CSA C22.2 No. 60950-1-07

NEBS Level 3 Compliance

  • GR-1089-Core: Sections 1-4, 7, 9, & 10
  • GR-63-Core: Sections 4.1, 4.2, 4.3, 4.4, 4.5, & 4.7
  • ETSI EN 300 019-2-1 v2.1.2: 2000-09
  • ETSI EN 300 019-2-2 v2.1.2: 1999-09
  • ETSI EN 300 019-2-3 v2.2.2: 2003-04
  • ETSI EN 300 132-2 V2.2.2: 2007-10



Server Technology TPC & GMT Fuses, and Circuit Breakers
Server Technology TPC & GMT Fuses, and Circuit Breakers
Buy individual TPC & GMT Fuses, and Circuit Breakers of various capacities.
ServerTech -48VDC PDU Expansion Unit, 4x70A Inputs / 4x70A Outputs
$3,570.00
ServerTech -48VDC PDU Expansion Unit, 4x70A Inputs / 4x70A Outputs
  • Rated Amperage: 4x 70A
  • Typical Power: 13.4kW
  • Outputs: High Current: (4) 70A
  • Circuit Protection: TPC Fuses
  • Inputs: (4) -48VDC Terminal Blocks (+/- & G)
  • Form Factor: 2.5U x 16"D x 17"W

Server Tech Temperature & Humidity Probe, 10 ft (EMTH-1-1)
$61.00
Server Tech Temperature & Humidity Probe, 10 ft (EMTH-1-1)
Temperature & Humidity Probe for Switched PDUs, 10 ft
 
Server Tech Rack Environmental Monitoring (EMCU-1-1B)
$234.00
Server Tech Rack Environmental Monitoring (EMCU-1-1B)
Server Technology Rack Environmental Monitoring (PDU or Standalone) - Supports 2 Temperature and humidity sensors, a Water sensor, and 4 Dry contact closure door sensors. Accepts 3rd party analog sensors (0 V to +5 VDC)
 
Water Sensor Probe, 1 ft detection cable, 10 ft connection cord
$73.00
Water Sensor Probe, 1 ft detection cable, 10 ft connection cord
Water Sensor Probe for the EMCU-1-1b Environmental Control Unit