NetBotz Wireless Sensor Pod 180

Please note, the APC NBPD0180 has been discontinued. For replacement options, please contact your Server Racks Online sales representative.

The APC The NetBotz Wireless Sensor Pod 180 (NBPD0180) connects to a NetBotz appliance and allows you to monitor the temperature and humidity (internal sensors included)  in a rack in your data center. The Wireless Sensor Pod includes 3 Universal Sensor ports for connecting additional sensors that allow you to monitor rack door access, and multiple temperature readings for the rack.

Compatible with NetBotz Room Monitor 455 (NBWL0455, NBWL0456), NetBotz Rack Monitor 450 (NBRK0451), NetBotz Rack Monitor 550 (NBRK0550), or NetBotz Rack Monitor 570 (NBRK0570). Room Monitor 455, Rack Monitor 550, and Rack Monitor 570 appliances support a total of 48 wireless devices on the wireless sensor network. The Wireless Sensor Pod 180 can be configured as the Coordinator, a Router, or an End Device in your wireless sensor network. NetBotz USB Coordinator & Router (NBWC100U) is used to connect the Wireless Sensor Pod to a NetBotz appliance when used in Coordinator mode, or to supply USB power when in Router mode.

Standard Lead Time: Usually in Stock

APC NBPD0180 - Click to enlarge

APC
Price: $279.99
NOW: $222.99
Save: $57.00
Dimensions4.2"H x 2.2"W x 1.1"D

NBPD0180 Features & Specs:

  • Wireless Range: 100 ft - line of sight
  • Internal Temperature & Humidity Sensors: Includes internal Temperature and Humidity sensors. Changes are reported via the user interface or e-mail.
    • Sensor Temp. Range: 1.6°C to 48.8°C (35°F to 120°F) +/- 1°C
    • Sensor Humidity Range: 10% to 90% non-condensing +/- 5% RH
  • 3 Optional sensors: Add sensors to compatible NetBotz Appliances for monitoring temperature, humidity, fluid, vibration, dust particles, etc.
  • Unique identifiers: Customize each sensor with a differentiating name and location.
  • Mounting: Front, Wall, Rear
  • Operating Environment: 32 - 113 °F (0 - 45 °C)
  • Storage Temperature: 5 - 149 °F (-15 - 65 °C)
  • Operating & Storage Humidity: 0 - 95%
  • Operating Elevation: 0-10000 feet (0-3000 meters)
  • Storage Elevation: 0-50000 feet (0-15000 meters)
  • Power:
    • Coordinator - Included AC adapter
    • Router - Via USB Coordinator & Router cable (NBWC100U)
    • End Device - 2 AA Batteries
  • Standard warranty: 2 years repair or replace
  • Compliance: RoHS, REACH (contains no SVHCs), CE, EMC Directive 2004/108/EC, ICES-003 Class B, FCC Part 15, EN55022, EN55024, EN 61326

Operating Modes:

Coordinator - Each NetBotz host appliance and wireless sensor network must have one and only one Coordinator.

Router - A Wireless Sensor Pod configured as a Router extends the range of the wireless sensor network and passes information back and forth from the Coordinator to the End Devices, and from itself to Coordinator. It also reports sensor data from its internal sensors and any attached external sensors.

End Device - An End Device monitors attached and internal sensors and sends data back to the monitoring appliance through the network. Any Wireless Sensor Pod powered by batteries is automatically configured as an End Device.

Includes:

  • NetBotz Wireless Sensor Pod 180 (includes internal Temp and Humidity sensors)
  • Plastic Push Rivets w/ sleeves (3)
  • Lithium Batteries (2)
  • #8 x 3/4-in Phillips head screws (2)
  • Plastic Wall Anchor (2)
  • Type A/B USB Cable
  • Wall-mounting bracket
  • AC Adapter
  • Literature Kit

Download IconAPC NetBotz POD 180 Manual (PDF)