Server Tech Sentry Smart PDU, 0U (CS-48VD2-L630)The Server Technology CS-48VD2-L630 is a 0U, 48 outlet, 30A, 208-240V, NEMA L6-30P, Sentry Smart
Rack PDU.
The Smart Cabinet Distribution Units (CDU) provide reliable power
distribution combined with local and remote power monitoring and environmental
monitoring via IP. Use the network interface to view power, temperature and
humidity levels via Web browser, or receive SNMP–based alarms when conditions
exceed de ned thresholds.
Server Tech CS-48VD2-L630Features:
- Input Current Monitor: Precisely measure the aggregate current draw (in
amps) on each power circuit. On-site verification of the input current with
the LED digital display. Remote verification via web browser or serial
screen.
- High Power Distribution: 120V and 208V ; 20 or 30-Amp power input feed
options.
- High Density: Dual input feed; 48 outlets per enclosure> IP Access &
Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, RADIUS,
LDAP, LDAPS, TACACS and RS-232 access
- Environmental Monitoring: Each Smart CDU supports two external temperature &
humidity probes and reports conditions thru the Web interface
- SNMP Traps: Provide automated alerts for power and environmental conditions
| 

Discount Pricing Available Call 1.866.722.5776 |  | |
| | Rack Units | Zero U |  | | Dimensions | 54"H x 3.5"W x 2.25"D |  |
| | Server Tech CS-48VD2-L630 Specifications:
| Mechanical |
|
| Height |
54 in. (1372 mm.) |
| Width |
3.5 in. (89 mm.) |
| Depth |
2.25 in. (57 mm.) |
| Input |
|
| Available Input Voltages |
208-240V, 50/60Hz |
| Available Input Cord |
NEMA L6-30P Cordset, 10 ft (3m) |
| Output |
|
| Outlets |
(48) IEC 60320/C13 |
| Amperage |
30A |
| Branch Circuit Protection |
Compliant to UL 60950-1 |
| Communications |
10/100 BaseT Ethernet
HTTP/HTTPS
SSLv3/TLSv1
SNMPv2
SSHv2
Telnet
LDAPv3/LDAPS
TACACS+
RADIUS
RS-232 (Serial) |
| Standards |
cTUVus – UL 60950-1-2003
CAN/CSA 22.2 No. 60950-1:2003
TUVGS – EN 60950-1:2001
FCC Class A, Part 15
CE
EMC-EN 55022 Class A, EN 55024 |
Server Tech Smart PDU Additional Features:
-
Branch Circuit Protection- The Sentry CDU Family
meets the UL 60950-1 requirement for branch circuit protection. Attention!
The Sentry CDU products meet the above criteria by providing overcurrent
protection with UL-listed Bussman SC fuses for each branch circuit.
-
Input Current Monitoring- The CDU’s exclusive True
RMS current monitoring is critical to preventing overloads in high-density
computing environments. LED digital displays on the CDU enclosure report the
input current of each phase or branch circuit.
-
Temperature and Humidity The Smart CDU supports two
external probes. Each of these probes measure both temperature and humidity.
Receive SNMP-based alert notifications when conditions exceed defined
thresholds.
-
Remote Power Monitoring- Monitor input power via IP
or serial interface.
-
HTTP/HTTPs Web Configuration & Control- Use the
Sentry Web interface to configure each unit's network settings. SNMP traps
for environmental & power thresholds and firmware updates. Also use the Web
interface to monitor key values, including amperage load(s),
temperature/humidity and other environmental conditions. SSL security
provides a secure HTTPs connection.
-
SNMP Management & Event Notification- The Sentry
family of products supports the Simple Network Management Protocol (SNMP).
This allows network management systems to use SNMP requests to retrieve
information such as input power, temperature and humidity. The Sentry
includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A
private enterprise MIB extension (Sentry3 MIB) is also supported to provide
remote power control. SNMP traps can be generated for various events,
including Input Current Load Thresholds (min & max), Temperature Thresholds
(min & max), Humidity Thresholds (min & max), water indication, and closed
contacts (cabinet doors open/close).
-
Zero U Enclosure- A vertical enclosure that occupies
Zero Vertical U of rack space in the equipment cabinet. It mounts on the
back rails or in the cavity space of the cabinet.
-
Secure Access - SSH or SSL Protection- Secure Shell (SSH),
known as Secure Socket Shell, is a Unix-based command interface and protocol
for securely getting access to a remote device. Sentry supports SSHv2.
Secure Sockets Layer (SSL) is a commonly-used protocol for managing the
security of a message transmission on the Internet. SSL is an integral part
of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.
-
Integrated Temp/Humidity Probe Support- Two (2)
RJ-style connectors located on the face panel of the PDU's enclosure provide
support for two (2) Integrated Temperature & Humidity Probes with ten-foot
(10') cables provide real-time measurements in the data center cabinet.
-
Firmware Flash Upgradeable- Access new firmware
updates via FTP for new firmware features and code releases. An update to
the firmware does not affect the status of the power outlets. Click here for
the latest
Firmware update.
-
LDAP/LDAPS-
The sentry family of products supports Lightweight Directory Access Protocol
(LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable
authentication with LDAP servers; user accounts do not need to be
individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry
product, and in the LDAP server) a set of necessary LDAP groups, and access
rights for each. User's access rights can then be assigned or revoked simply
by making the user a member of one or more pre-defined Sentry LDAP groups.
User account can be added, deleted, or changed in the LDAP server without
any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
- Microsoft Active Directory (MSAD)
- Novell eDirectory (eDir)
- Open LDAP
-
RS-232 Control-
Serial control via any device with a bi-directional serial port, including a
PC, laptop, KVM switch, Console Port Access switch, or terminal server.
-
20 or 30 Amp Power Input Support-
20-amp power input support - IEC320/C20 power inlet receptacles supports any
power cord with IEC320/C19 power connector (PTCORD-XX). 30-amp power input
support provides hard-wired 10' cord and appropriate L5-30 or L6-30 plug
type.
|
|
|