60kVA Power Distribution Center w/ (2) 42-Pole Distribution Panels and 208V Service Bypass
Tripp Lite's SUDC208V84P60M Power Distribution Center supports 60kVA 3 phase UPS power distribution in critical datacenter equipment racks. Integrated 3 breaker 208V service bypass enables hot-swappable replacement of 60kVA 3 phase UPS systems without dropping the connected critical loads. Full size 42U rack enclosure with two pre-installed 42 pole circuit breaker panels support 3 phase 208V and single phase 208V and 120V output via optional corded receptacle whips. Each breaker panel includes 225A, 3 pole main breaker, ground and neutral bars, plus 1/2, 3/4 and 1 inch knockouts.
Full size 42U Rack Power Distribution Center supports 60kVA 3 phase UPS power distribution in datacenter equipment racks
Integrated 3 breaker 208V service bypass enables hot-swap replacement of 60kVA 3 phase UPS systems without dropping the connected critical loads
Each 42 pole breaker panel supports 3 phase, 208V and single phase 208V and 120V outputs to connected equipment
Each breaker panel includes a pre-installed 225A, 3 pole main breaker, ground and neutral bars
Secure front and rear doors, removable side panels
Full line of accessories includes circuit breakers, corded receptacle whips and PDUs
Product Features
SUDC208V42P60M Power Distribution Center supports 60kVA 3 Phase UPS power distribution in critical datacenter equipment racks
Integrated 3 breaker 208v service bypass switch enables hot-swappable replacement of 60kVA 3 phase UPS systems without dropping the connected critical loads
Full size 42U rack enclosure with two pre-installed 42 pole circuit panel supports 3 phase 208V and single phase 208V and 120V outputs via optional corded receptacle whips, snap-in panel breakers and PDUs
Line up and match power distribution cabinet blends with existing standard datacenter racks for an aesthetically pleasing appearance while providing convenient connectivity between the centralized 3 phase UPS and protected electronic devices in equipment racks
Each breaker panel includes 225A 3 pole main breaker bypass switches, ground and neutral bars, 1/2, 3/4 and 1 inch knockouts
Rack enclosure offers secure front and rear doors, removable side panels and shares common dimensions and overhead wiring tray and ladder accessories as Tripp Lite SR42UB equipment racks
Requires appropriate SUBB-series output circuit breakers(see Related Items for list of compatible SUBB breakers)
Optional full line of basic, metered, monitored and switched PDUs