Powerware PW5125-1000 Tower UPS

To view other UPS options, please visit our UPS Power page.

The Powerware PW5125-1000 Line-interactive Tower UPS delivers cost-effective power protection for PCs, workstations, and servers.

  • ABM technology significantly increases battery service life
  • Buck and Double Boost voltage regulation corrects voltage fluctuations and delivers pure sine wave output
  • Extended runtime capability with Extended Battery Modules (EBMs)
  • Load segments maximize runtime for critical devices
  • Hot-swappable batteries simplify service
Powerware PW5125-1000 Tower UPS

Eaton Powerware

Price
$481.00
Sale Price
$432.90
Savings!
$48.10
Free Project Eval

PW 5125 1000 Specifications:

Mechanical  
Dimensions (HxWxD) 9.45 x 6.38 x 15.79 in. (240 x 162 x 401 mm.)
Weight 34.3 lbs. (15.6 kg.)
Electrical Input  
Power Rating 1000VA / 700W
Nominal Voltage 120 Vac
Input Voltage Ranges (for user-selectable voltages) Low voltage: 77-152 V; High voltage: 154-288 V
Operating Frequency 50/60 Hz, Auto-sensing
Frequency Range 46-65 Hz
Connections  
Input Connections 5-15P, 6 ft line cord
Output Receptacles (6) 5-15R
Battery  
Battery Type Sealed, lead-acid; maintenance free
Battery Replacement Hot-swappable internal batteries and external batteries modules
Recharge Time <3 hours to 90% usable capacity
Start-On-Battery Allows start of UPS without utility input
Electrical Output  
On Utility Voltage Regulation -10% to +6% of nominal
On Battery Voltage Regulation  ±5% RMS
Voltage Wave Shape (on battery) Sine Wave
Output Protection Short circuit protection
Communications  
User Interface Front Control Panel
Audible Alarms For various UPS alarm conditions, including: On Battery, Low Battery, Overload, UPS fault
Network Transient Protector  UL 497 A, in/out jacks RJ45 (high voltage models network protection) &
RJ11 (low voltage models modem protection)
X-Slot Interface RS-232 Single Serial Card (standard),
other options available: See available Options Chart
Cable 6-foot communications cable included
Power Management Software Powerware Software Suite CD-ROM (bundled with UPS)
General  
Diagnostics Full system self-test on power up
UPS Bypass No Bypass, Internal Bypass
Transfer Time 2-4ms typical
Overload (normal operation) 110% overload, shutdown after 3 minutes.
150% overload, shut down 10 cycles
Environmental  
Operating Temperature 0 to 40º C (32 to 104º F)
Storage Temperature -15 to 50º C (5 to 122º F)
Relative Humidity 0% to 95% non-condensing
Lightning & Surge Protection ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5
Surge Energy Rating 480 Joules
Audible Noise Less than 40 dBA typical
 Altitude 3000m (10,000 ft) without derating

   