STI PRO2 Smart/Switched PDU 22.0kW, 230/400V 3-Phase Wye, 32A, 36 x C13 & 12 C19 outlets

The Server Technology C2W48CE-4PAF2M66 PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP.

  • Input Capacity - 22kW
  • Input Voltage - 400V
  • Input Cord - 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr
  • Input Phase - 3-Phase Wye (L-N)
  • Input Current - 32A
  • Output - (36) x IEC 60320/C13; Global Rating: ≤ 10A @230V L-N
    & (12) x IEC 60320/C19; Global Rating: ≤ 16A @230V L-N
  • Max Operating Temperature - 60 °C
Server Technology C2W48CE-4PAF2M66 - Click to enlarge



Price
$2,725.00

Mounting Bracket Options
Include Mounting Bracket KIT-MBVPT-1B (no charge)
No Mounting Bracket Needed

Server Tech C2W48CE-4PAF2M66 Switched PDU Features:

  • Network Monitoring - Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more
  • Hot-Swap Network Card - Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.
  • Star Multi-Linking - Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
  • Temperature/Humidity Monitoring - Master and Link units each support two external 10' (3m) T/H probes (sold seperatly). Receive SNMP-based alerts and email notifications.
  • Auto-Flip Current Display - Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
  • Per-Inlet Power Sensing - Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
  • Branch Current Monitoring - PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
  • Branch Circuit Protection - This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
  • Outlet Control - On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
  • Alternating-Phase Outlets - 3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.
  • High Density Outlet Technology - The highest outlet density available in a network connected PDU. Meets IEC C13 and C19 specifications, plus high native retention and UL94V-0 flame rating
  • High Temperature Rating - This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible Mounting - Includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).
  • Color Identification - Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black. (To order colors other than black or for more inforamtion, please call your Server Racks Online representativce at 1-866-722-5776.

Server Tech C2W48CE-4PAF2M66 Specifications:

Mechanical 
Height 80 in. (2032 mm.)
Width 2.2 in. (56 mm.)
Depth2.5 in. (64 mm.)
Input
Available Input Voltages3-Phase Wye, 400V
Available Input Cord230/400V Wye 32A IEC 60309 3P+N+PE 6Hr
Output 
Outlets(24) IEC 60320/C13
(12) IEC 60320/C19
Amperage32A
Branch Circuit ProtectionUL498 Compliant 1-pole, 20A trip circuit breakers, six (6) branch, rating: ≤ 16A
Communications10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
StandardsTUV T-Mark to EN 60950-1:2006+A11+A1+A12+A2
EMC to EN55024 (2010) and EN55022 (2010)
CE Compliant
RoHS, European Hazardous Materials Directive (Recast) 2011/65/EU
WEEE Compliant


Server Rack Cable Management
Server Rack Cable Management
Cable Management Rings, Rackmount Cable Organizers, Cable Ties, Patch Panels, Cat5 Patch Cables, Fiber Optic Cables, Power Cords
 
zLock Dual-side Locking Power Cables
zLock Dual-side Locking Power Cables
Eliminate accidental and vibration power cable disconnects - zLock is the only universal locking power cord that locks both ends.
Power Cords & Extension Power Cords
Power Cords & Extension Power Cords
Power Cords & Extension Cords available in a huge variety of connectors and cord lengths!
 
UPS Backup Power - Rack Mount & Tower UPS
UPS Backup Power - Rack Mount & Tower UPS
Off Line (Basic), Line Interactive (Intermediate), and On Line Double Conversion (Advanced) Uninterruptable Power Systems
 
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatic Transfer Switches (ATS) - Fail-Safe Power Redundancy
Automatically switch power inputs if either in-feed goes down - Fail-Safe N+1 Power Redundancy.