The Top 5 Things to Keep in Mind When Buying a Computer Rack

Computer Rack enclosures are integral to the success of your organization because they provide the platform that houses the mission-critical equipment your business depends on. Selecting the right Computer Rack will help effectively power, cool, and protect your equipment; keep your business running smoothly by reducing potential downtime; and make the management and organization of your datacenter more efficient. Here are five things to consider:

Select An Appropriately-Sized Rack

Select a Computer Rack with sufficient internal space to house your current equipment and ensure that you have ample space to accommodate planned future expansion as well as any unplanned equipment purchases. Rackmount equipment is measured in the Electronic Industries Alliance (EIA) standard "Rack Units" or Rack "U". One "Rack Unit" is equal to 1.75" in height. Keep in mind that space for accessories, such as environmental monitoring devices, remote power management devices, rack mount LCD monitors, and battery back-up, may be necessary. For example, if you need to accommodate 20 2U servers, you would likely want to choose a rack with a height of 44U to accommodate accessories such as a 1U patch panel, as well as a 2U UPS back-up battery. A rack's internal height is measured from the tallest point of any side rail to the bottom chassis; internal depth is measured from the insides of both front and rear doors; and internal width is measured from one side panel to the other. Be sure that the rack's external dimensions can be accommodated in the floor space allotted for it, check that it can be safely moved through all doorways, and ensure that its placement meets any relevant clearance or safety regulations. As a note, always use appropriate rack-loading techniques, including placing heavy items at the bottom of the rack to prevent a rack from becoming too top-heavy, have a plan about what you want to put toward the front and back of the rack (based on how much you will need to access or remove equipment), and have someone help load equipment that is heavy and/or above the height of your head.

Physical Security Starts Here

Proper security is vital to the overall well-being and the function of your business. Knowing how your Computer Rack fits into your overall security strategy is just as important. There are several measures you can take to improve the security of the racks and equipment in your datacenter. To begin with, consider purchasing Computer Racks that have locking front and rear doors, as many models offer this option. Second, use environmental monitoring devices to proactively monitor your racks. In addition to allowing administrators to continuously monitor amperage draw per circuit, water leaks, temperature, and other variables, and sending alerts automatically via SMTP/SMS/SNMP when conditions exceed established thresholds, several environmental monitoring devices have door sensors that support "normally open" or "normally closed" conditions and can alert administrators when a cabinet door has been opened. (When a change in state relative to its defined threshold occurs, the device reports an "error" condition.) In addition, there are devices available that work with docked camera pods and sensor pods to allow administrators to continually visually monitor Computer Racks and rooms, as well as record audio clips. If you are planning a new datacenter, you might also consider additional physical security measures such as building the datacenter away from a main road, limiting windows in the datacenter, and providing secure entrances and exists.

Tailor Your Rack Design To Work For You

Most manufacturers will allow you to select from many options so that your Computer Rack meets the specific requirements of your environment. There are several common areas that you should be able to select options from.
Shelving: Most manufacturers offer several Computer Rack shelf options, including adjustable or fixed server shelves with four-point mounting; sliding keyboard shelves with 2-point mounting; vented, heavy-duty, or cantilever shelves; and media shelves. Choose a Computer Rack shelf with a depth of 6 inches less than the overall depth of the rack - for example, if you have a 30-inch deep cabinet, choose a shelf with a depth of 24 inches.
Top and Side Panels: Top panels protect equipment from foreign materials. Options include perforated slots for added ventilation, grommet holes for supplementary cable management pathways, and mounting for exhaust fans. Side panels offer security and are often available in several options: solid fixed, solid removable, and solid with vents (louvered).
Mounting Rails: Most racks come with two sets of mounting rails. However, additional sets of rails can be ordered to accommodate different depths and facilitate rack loading. Most manufacturers allow you to choose from Universal Mounting Rails (square holes fitted with cage nuts) or EIA Standard rails (with 10/32 tapped holes). Universal rails will support 19" EIA width rackmount and networking equipment and almost all server equipment. EIA Standard Mounting Rails support 19" EIA width rackmount and networking equipment and some server manufacturers' rack mounting equipment. Whether the rails have square or tapped holes, all mounting rails comply with the ANSI/EIA-310-D standard (1992). Most major enclosure manufacturers recommend rails with square holes and cage nuts, and currently most off-the-shelf rack models utilize rails with square holes.
Feet: Available "feet" options include retractable anti-tip feet to stabilize mid-to top-heavy loaded racks; casters that attach to the bottom of server cabinets to help maneuver racks; and levelers that should be used if casters are implemented to ensure that the rack remains level once it has been moved from one place to another.

Consider The Latest Power Technologies

Power Distribution Units (PDUs) evenly disperse power to servers over the entire power strip. Rack mount power strips are specifically made for Computer Racks and mount vertically or behind mounting posts in the back portion of a cabinet. Power strips fall into two categories: standard and intelligent. While standard power strips have some features that can provide valuable information, such as fuse replacement indicators and current output displays, they must be managed in-person and on-site. In contrast, intelligent power strips provide remote power control, which allows administrators to perform a cold reboot of servers and devices and troubleshoot problems from any location with an internet connection, reducing server downtime and getting vital business functions back online quickly. Remote power products not only provide intelligent control of attached systems, they also allow administrators to leverage leading advances in power distribution, such as 3-Phase power. Three-Phase power technology is not exclusive to remote power management products, but many solutions can accommodate or incorporate it. Compared to single-phase power, 3-Phase power uses fewer circuits, provides a more balanced power load, reduces the overall number of PDUs needed to power equipment, and significantly increases available amperage into the Computer Rack. As an example, in a traditional rack environment, (4) 20-amp circuits would be required for 64 amps of available power (assuming a maximum 80% load). In contrast, a 3-phase circuit can provide up to 51.6 amps per circuit, or more than 82 amps of available power, while only requiring 2 circuits (assuming a maximum 80% load). The cost savings of 3-Phase power is beneficial, especially since experts estimate that in the future, electricity costs could rise from current levels of 10 percent or less of IT budgets to 20-30 percent (3). Other power-related aspects to keep in mind include the number of outlets you will need, plug/receptacle requirements, and redundancy requirements.

Know Your Cooling Strategy

Understand the role that Computer Racks play in your complete data center cooling strategy. The type of rack you choose will depend on the cooling methods used in your environment. Baseline kW of heat output per rack varies widely, depending on type and density of equipment, and can be anywhere from 4 kW-12 kW or more per rack, with some experts estimating that the rise of high-density environments and designs for future equipment will result in an output of 30-50 kW per rack. (4)

Fully Perforated Racks: Select a fully perforated rack for maximum air flow if the primary method of cooling in your datacenter or server room will be ambient air cooling (fans, air handlers, blowers, and/or Computer Room Air Conditioning (CRAC) units and a raised floor).

Fully-Sealed Racks: Choose a fully-sealed rack if a liquid cooling unit or rack air conditioner will be used in your environment.
As power-intensive applications and server densities have increased, Liquid Cooling Units (modular, temperature-neutral high-density cooling solutions that utilize air/water heat exchangers to provide uniform, effective cooling) are increasingly being used. One of the main benefits of self-contained liquid cooling units is that they result in little or no impact on the existing HVAC system. Liquid cooling units are mounted at the rack base, in a rack "side car" with three cooling modules possible per equipment rack, and can provide a total cooling capacity of 30kW.

Rack air conditioners are generally not used in traditional datacenter environments that have adequate CRAC systems. However, if IT equipment will be placed outside of a controlled datacenter environment, such as in a warehouse or factory, rack air conditioners are sometimes used. It is important to keep in mind that rack air conditioners are intended for use in industrial and large spaces, they generate condensation and noise, and they exhaust hot air into the room where the enclosure is located. In a large room, the heat will dissipate. In a smaller room or confined space like a closet, the exhausted hot air from the AC unit can cause the room to overheat. If an AC unit is used in a small room, measures must be implemented to exhaust the hot air from the room. Air conditioner models differ in the amount of cooling output they can provide, so select one appropriate to your needs.

Below are formulas to help calculate heat load and select a rack air conditioner.

  • Add up the wattage of each device and convert it to BTU (a device's manual usually lists its wattage). You can also determine wattage with the following formula (Watts=Volts X Amps).(5) Remember that 1,000 Watts=1kW.
  • If a rack air conditioner will be used, for every 1 kW consumed, consider that 3412.14 BTU is generated. Air conditioners are rated for different BTU levels.

Additional Tips
Other ways to improve cooling include using blanking panels to manage air flow efficiency, selecting a rack with built-in channels for better cable management and improved air flow, and removing any obsolete or unnecessary equipment from the rack. In addition, consider that 3-phase power can significantly increase available amperage into the Computer Racks, reducing the overall number of PDUs needed to power equipment and leaving more space for airflow.